These are called electrical zones.
Bathroom lighting zones uk.
This was previously known as zone 3 and is essentially anything in the bathroom that is not zones 0 2.
Lighting in the bathroom is important.
For example zone 0 covers areas inside baths or showers.
When thinking about lighting for your bathroom it is important to think about the below bathroom zones to ensure the lighting you want can be installed in your desired location.
These are the areas beyond zones 0 1 and 2.
Zone 0 bathroom lights are for the inside of the bath or shower itself.
Zone 1 is for use inside a shower cubicle and around a bath and has a minimum ip rating of ip65 zone 2 is for use on the wall up to a height of 2 25m again having a minimum ip rating of ip44.
When decorating or installing a bathroom one of the things that needs considering is the positioning of these electrical items in relation to your bath or shower.
Update to ip ratings in 20 march 2015.
A range of bathroom lighting including zone 1 2 3 lights rated for use in different areas of the bathroom.
The astro lighting avola 0962 led bathroom wall light is an energy saving polished chrome led wall lamp with an ip44 rating.
The three bathroom zones are.
Why do bathroom lights have an ip rating.
Nowadays bathroom technology is booming and more and more electrical appliances are being installed in britain s bathrooms.
The extent of zone 2 when using uk bathroom electrical safety zones.
0 1 2 and 3.
The lower the zone number the higher the ip rating needs to be.
If lighting is required in there any fitting used must use a low voltage supply that is a maximum of 12v and also be rated at least ipx7 which.
This is the area directly above a bath and within a shower cubicle.
Window recesses that extend into the area zone 1 occupies is also considered as zone 2.
Any fitting used in this zone must be low voltage max 12v and be rated at least ip67 which is total immersion proof.
The diagram shows a bathroom split into four clear zones.
This is the area within a bath tub only 12v selv safety extra low voltage equipment can be used.
Any fitting used in this zone must be low voltage max 12v and be rated at least ip67 which is total immersion proof.
Zone 1 bathroom lights can be used in the area above the bath to a height of 2.
Zone 2 same as above requires a minimum of ipx4.
The bathroom zone number refers to the amount of water likely to be present.
Most bathroom light fittings are ip20 or above rated and depending on their ip rating they can be mounted in the different zones in the bathroom.
Bathroom zones are areas where electrical equipment must offer a certain degree of protection against water.
Regulations are very strict as to which lights you are able to use in a bathroom and to complicate matters bathrooms have different zones which determine what type of light you may use within that zone.
Zone 0 this zone requires a minimum of ipx7.
These areas must have a particular.
Zone 1 requires a minimum of ipx4.