Comtran s line of vitalink cable featuring fplr circuit integrity cable is designed for use in a wide range of critical systems including emergency voice alarm communication evac smoke fire alarm systems fireman s telephone and area of refuge communication systems and visible.
2 hour rated fire alarm mc cable.
Ed walton a consultant to the wire and cable industry said.
Comtran vitalink 2 hour fire rated cable 18 2 fire alarm cable fplr riser unshielded color.
The ul fhit number system for each manufacturer s product type describes the tested installation of cable components and assembly which leads to its certification as a two hour fire rated system.
Cable tray rated install per nec federal specification a a 59544 formerly j c 30b ul classified 1 2 and 3 hour through fire penetration product r14141 nfpa 262 formerly ul 910 plenum rated type fplp made in usa of us and or imported materials fire alarm control cable type mc dual rated type mc fplp.
Refer to r27557 fire resistive cable ul vitalink brand type fplr ci st1 cmr ci ls cl3r ci st1 for use in system no.
Download spec sheet pdf 132 19kb add to quote.
Fplp fire alarm cable view pdf.
Fire alarm cable shielded 300v 18 awg 2 conductor solid bare copper pvc aia csa ft4.
So how is it that we have codes in place to insure that our fire alarm circuit pathways are secure for a period of 2 hours but not the control or notification equipment.
Download spec sheet pdf 105 11kb add to quote.
Fhit 40a and fhit7 40a for use as cic cable installation follows fhit 40a fhit7 40a and comtran s installation instructions.
Vitalink mc 2 hour cable 600v 350 awg 3c.
120 of the ul fire resistance directory.
2 type fplr fplr power limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor all fplr cables are listed as having fire resistant characteristics capable of preventing fire from traveling from floor to floor riser cables must pass both ul test 1424 and the vertical riser.
Vitalink 2 hour fire rated ci cable applications.
Ul listed nec type mc in accordance with ul standard 1569 2 hour fire rated per ul standard 2196 following astm e119 1 850 f with water hose stream electrical circuit integrity systems fhit system no.
For use as ci cable installation follows the nec and local code.
The cable s electrical listing is not affected by this qualification and.
Fire alarm cable in simpull coilpak wire payoff and simpull barrel cable drum view pdf.
The facu or fire alarm control unit is not required to be 2 hour rated nor are the field devices such as fire fighter s telephone jacks speakers strobes horns etc.
Red alert type mc fplp fire alarm and control cable view pdf.
Fa 5c 16 round shld csa.
Vitalink mc 2 hour fire rated cable 600v 350 awg single conductor cwca csa.
Emergency voice alarm communication smoke and fire alarm systems fireman s telephone and area of refuge communication systems visible notification appliances compliances.
Fplr fire alarm cable view pdf.