No you can t according to code.
14 2 electrical wire amp rating.
Usually a general purpose house circuit is designed for 20.
The amperage rating of a cord is a function of the wire gauge number of current carrying conductors and length of the cord.
1 current ratings for up to 1000 v pvc insulated single and multicore wiring cables ambient temperature up to 30 o c values for resistance are based on electrical resistivity for copper 1 724 x 10 8 ω m 0 0174 μω m and electrical resistivity for aluminum 2 65 x 10 8 ω m 0 0265 μω m.
Wire size chart and maximum amp ratings.
Common sizes include 14 12 10 8 6 and 2 gauge wire.
Common us awg wire gauges and amps ratings.
2 3 or 4 3 or 4.
Custom overhead electrical drops.
You must use the correct size wire for the current load requirement of the circuit to prevent the wire from overheating.
Wire size and amp ratings.
The number and type of electrical devices connected to a circuit determine the ampacity requirement of the conductor.
13 amps 10 amps.
For the 00 000 0000 etc.
The gauge of the wire dictates the amount of current that can safely pass through the electrical wire.
2 3 or 4 3 4 or 5.
The higher the gauge number the smaller the.
Current is measured in amperes or amps.
Then divide the total wattage by the voltage of the system 110 or 220 and that will give you the expected current or amps.
In the american wire gauge awg system wire size diameters can be calculated by applying the formula d awg 005 92 36 awg 39 inch.
Awg wire sizes see chart below awg.
60 c 140 f 75 c 167 f awg mm copper.
View wire size and amp ratings in a new window.
The tables below are intended to be a general guide for wire size and amp ratings.
18 amps 15 amps.
Gauges you use 1 2 3 which makes more sense mathematically than double nought.
In real life you can do this and a 14 gauge wire can carry 20 amps safely but the problem is that it s not safe to do this in a house.
Electrical current is measured in ampacity and each wire gauge has a maximum safe carrying capacity.
As a guide 14 wire is good for 15 amps 12 wire is good for 20 amps 10 wire is good for 30 amps.
Electrical current is measured as ampacity.
The wire size chart below shows allowable ampacities of insulated conductors rated up to and including 2000 volts 60 c through 90 c 140 f through 194 f not more than three current carrying conductors in raceway cable or earth directly buried based on ambient air temperature of 30 c 86 f.
To calculate the amperage for a circuit first add up the wattage of all the electrical devices that will be on the circuit.
Custom portable outlet box.